Sunson Feed Enzymes Department was established in 1998. Till now, SUNSON brand has been already accepted by customers domestically and aboard by concentrating on feed enzymes production and application technology.Sunson feed enzymes are ideal solutions for: Saving feed cost; Non-starch polysaccharides (NSPs) breaking down; Endogenous enzymes supplement; Reducing the phosphorus burden on the environment.
â—SINGLE ENZYMES
Animal Feed Enzymes,Animal Liquid Feed Enzyme,Enzyme For Animal Feed,Neutral Protease Feed Additive Sunson Industry Group Co., Ltd , http://www.sunsonchinaenzymes.com
Model:UN2000B
Waveform:ECG and SPO2 waveforms
Features:
Touch screen,5.0 inch color TFT-LCD, simple for operating, quickly&accurately measure the data Build-in rechargeable Li-battery, up to 15Â hours running time, support AC and DC power Adjustable audible and visual alarms, and sensor off alarm Long time monitoring and sleeping monitoring Easy to carry, suitable for ambulance center, has the stand for fixing ETCO2, FiCO2 and RR are optional
Priors
Â
Storage and review data up to 3888groups via Trend Graph and Trend List USB and Bluetooth data upload Big font screen interface is easy to observe Back light can be adjusted Free advanced software are all standard on free Optional Bluetooth printer to print the waveform and data out
Parameters
ECG
Input:5- lead ECG cable, standard AAMI cable connector
Lead Selection:I,II,III, avR,avL,avF,C
Gain Selection:×1,×2,×4,×8
Sweep Speed: 12.5, 25, and 50 mm/s
Frequency Response: None filter: 0.05~100Hz (-3dB), filter: 0.5~40Hz (-3dB)
Calibration Signal: 1mV square wave
Protection: Against electrosurgical interference and defibrillation
Heart Rate
Measuring Range: 20 bpm~300 bpm
Renew Time: 1 time per beat
Accuracy: ±1 bpm
Alarm Mode: Audible and visual alarm
SpO2
SpO2%
Measuring Range:0%~100%
Resolution:1 %
Accuracy:±2 %(90%~99%), ±3 %(70%~89%),unspecified (0%~69%)
Pulse Rate
Measuring and Alarm Range:20~300bpm
Resolution: 1bpm
Accuracy: ±1bpm
NIBP
Method: Oscillometric
Mode: Manual, Auto, STAT
Measuring Interval in AUTO Mode: 1, 2, 3, 5, 10, 15, 20, 30, 45, 60 (min)
Measuring Period in STAT Mode: 5 min
Cuff Pressure Range:0 mmHg~300mmHg
Pulse Rate Range:30 bpm~250bpm
Measurement Rage: Adult 30 mmHg~255mmHg, Pediatric 30 mmHg~160mmHg
Over-pressure Protection: Adult 300mmHg, Pediatric 220mmHg
Pressure Resolution : 1mmHg
The SYSTOLIC and DIASTOLIC values measured using this device shall be equal to those
measured by trained medical personnel using cuff and stethoscope. The MEAN value measured
using this device is equal to that measured using blood pressure measurement device.Â
Temperature
Input: Body surface thermal-sensitive resistor temperature sensor
Measuring Range: 0ºC~50ºC
Accuracy: ±0.1ºC
EtCO2(Optional)
Measuring Range: Â 0~150mmHg
Resolution:Â 1 mmHg
Accuracy: ±2mmHg@< 5.0% CO2
Respiration Rate(Optional)
Measuring Range: 0~120rpm
Resolution: 1rpm
Accuracy: ±1rpm
Printer (optional)
Type: Thermal micro-printer
Printer Paper: 58 mm thermal paper,Paper roll diameter≤Φ 33mm
Interface: Bluetooth wireless interface
Recording Types: Real-time printing and review data printing
Power Supply:
Rechargeable battery 1700mAh~2000mAh.7.2V. Â
Charge(discharge) >=1000times.
Charge time: 2hours
Work Operation/relative humidity:0~55ºC/10~80%RH
Storage Operation/relative humidity:-20~60ºC/10~90%RH
Payment
Shipping
Â
Model:UN2000B
Waveform:ECG and SPO2 waveforms
Features:
Touch screen,5.0 inch color TFT-LCD, simple for operating, quickly&accurately measure the data Build-in rechargeable Li-battery, up to 15Â hours running time, support AC and DC power Adjustable audible and visual alarms, and sensor off alarm Long time monitoring and sleeping monitoring Easy to carry, suitable for ambulance center, has the stand for fixing ETCO2, FiCO2 and RR are optional
Priors
Â
Storage and review data up to 3888groups via Trend Graph and Trend List USB and Bluetooth data upload Big font screen interface is easy to observe Back light can be adjusted Free advanced software are all standard on free Optional Bluetooth printer to print the waveform and data out
Parameters
ECG
Input:5- lead ECG cable, standard AAMI cable connector
Lead Selection:I,II,III, avR,avL,avF,C
Gain Selection:×1,×2,×4,×8
Sweep Speed: 12.5, 25, and 50 mm/s
Frequency Response: None filter: 0.05~100Hz (-3dB), filter: 0.5~40Hz (-3dB)
Calibration Signal: 1mV square wave
Protection: Against electrosurgical interference and defibrillation
Heart Rate
Measuring Range: 20 bpm~300 bpm
Renew Time: 1 time per beat
Accuracy: ±1 bpm
Alarm Mode: Audible and visual alarm
SpO2
SpO2%
Measuring Range:0%~100%
Resolution:1 %
Accuracy:±2 %(90%~99%), ±3 %(70%~89%),unspecified (0%~69%)
Pulse Rate
Measuring and Alarm Range:20~300bpm
Resolution: 1bpm
Accuracy: ±1bpm
NIBP
Method: Oscillometric
Mode: Manual, Auto, STAT
Measuring Interval in AUTO Mode: 1, 2, 3, 5, 10, 15, 20, 30, 45, 60 (min)
Measuring Period in STAT Mode: 5 min
Cuff Pressure Range:0 mmHg~300mmHg
Pulse Rate Range:30 bpm~250bpm
Measurement Rage: Adult 30 mmHg~255mmHg, Pediatric 30 mmHg~160mmHg
Over-pressure Protection: Adult 300mmHg, Pediatric 220mmHg
Pressure Resolution : 1mmHg
The SYSTOLIC and DIASTOLIC values measured using this device shall be equal to those
measured by trained medical personnel using cuff and stethoscope. The MEAN value measured
using this device is equal to that measured using blood pressure measurement device.Â
Temperature
Input: Body surface thermal-sensitive resistor temperature sensor
Measuring Range: 0ºC~50ºC
Accuracy: ±0.1ºC
EtCO2(Optional)
Measuring Range: Â 0~150mmHg
Resolution:Â 1 mmHg
Accuracy: ±2mmHg@< 5.0% CO2
Respiration Rate(Optional)
Measuring Range: 0~120rpm
Resolution: 1rpm
Accuracy: ±1rpm
Printer (optional)
Type: Thermal micro-printer
Printer Paper: 58 mm thermal paper,Paper roll diameter≤Φ 33mm
Interface: Bluetooth wireless interface
Recording Types: Real-time printing and review data printing
Power Supply:
Rechargeable battery 1700mAh~2000mAh.7.2V. Â
Charge(discharge) >=1000times.
Charge time: 2hours
Work Operation/relative humidity:0~55ºC/10~80%RH
Storage Operation/relative humidity:-20~60ºC/10~90%RH
Payment
Shipping
Â
PHYTASE
PROTEASE
XYLANASE
AMYLASE
GLUCO OXIDASE
ALPHA GALACTOSIDASE
ACID MANNANASE
SWINE
WHEAT DIET
POULTRY
MISC.GRAIN AND MEAL
REGULAR DIET
Model NO.: UN2000B
OEM: Support
Display: 5 Inch TFT-LCD
Bluetooth: Support
Gross Weight: 1kg
Touchscreen: Yes
Etco2: Optional
Bluetooth Printer: Optional
Net Weight: 655g
Dimension: 209X;104X47.5(mm)
Trademark: Union Medical
Transport Package: Carton
Origin: China
HS Code: 9018193010
Model NO.: UN2000B
OEM: Support
Display: 5 Inch TFT-LCD
Bluetooth: Support
Gross Weight: 1kg
Touchscreen: Yes
Etco2: Optional
Bluetooth Printer: Optional
Net Weight: 655g
Dimension: 209X;104X47.5(mm)
Trademark: Union Medical
Transport Package: Carton
Origin: China
HS Code: 9018193010
(UN2000B) Hot Sell Portable/Handheld Touchscreen  Vital Sign  Monitor with bluetooth
(UN2000B) Hot Sell Portable/Handheld Touchscreen  Vital Sign  Monitor with bluetooth