bale wrap netting have different sizes. usually width 1.23m,1.25m, 1.28m, 1.3m, 1.5m, etc.
Bale Wrap netting from MaoYang are made of 100% virgin material and environmental friendly.
Bale wrap netting are stacked on pallet for delivery and transport.
1.25m width*3600m bale wrap netting, 4' bale netting, 4' wrap netting Zibo Maoyang Industry and Trading Co.,ltd , http://www.mysilage.com
Features:
1. 4.3" color TFT LCD screen (LED backlight), with resolution 272×480
2. Three working modes: Rate/Time/Volume mode
3. Drug library with 210 kinds of medicine
4. Storage 1500 history records
5. Heating function, suitable for infusing in winter or there is requirement for the fluid medication temperature
6. Support multi language display
7. AÂ variety of visible and audible alarm, make infusion more safe
Â
Large LCD display, with backlight, suitable for working in various ambient light conditions.
Disposable IV set of any brand is suitable for this pump
Three working modes: Rate/Volume/Time mode
Purge, KVO function
Heating function is optional, suitable for infusing in winter or there is requirement for the medication temperature.
Remote Controller makes operating more convenient.
Central monitoring system is optional, the infusing status of each pump is displayed in real time at the central station through wireless transmission.
Simple and convenient in operating, intuitive presence of working status.
Audible and Visible alarms
Alarm: Infusion Complete, Empty, Faulty Signal, Misoperation, Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle.
Size: 188 mm(L)*198 mm(W)*228 mm(H)
Net Weight: 2.2kg
Standard:Drug library, History record, Heating function, Drip detector
Optional:SpO2,NIBP
Why we add NIBP &SpO2 to an infusion pump?
NIBP & SpO2 are the most frequently used vital sign parameters, we  make them work as one, to help doctors reduce cost and save space  which is already very limited in the hospital room.
Technical data sheet:Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â
Pump Type
Drip type infusion pump
Pumping Way
Peristalic fingers
Adjustable Drop Rate Range
1~400 drops/min (step: 1Â drop/min)
Adjustable Volume Rate Range
1~1200 ml/h (when 1~99.9 ml/h, step: 0.1 ml/h; greater than 99.9 ml/h, step: 1Â ml/h)
Flow Precision
Within 3% more or less(using the IV set appointed by the manufacturer or calibrated high quality IV set)
Mechanical precision
within 2% more or less
Purge Rate
800 ml/h
KVO Rate
1 ml/h (1~300 ml/h)
3 ml/h (greater than 300 ml/h)
Infusion Volume Range
1 ml~9999.9 ml (step: 0.1 ml)
Maximum Accumulated Volume
9999.9 ml (step: 0.1 ml)
Â
Time Range
1 min~9999 min (step: 1Â min)
Occlusion Alarm Threshold
High: 800 mmHg+-200 mmHg (106.7kPa+-26.7kPa)
Medium: 500 mmHg+-100 mmHg (66.7kPa+-13.3kPa)
Low: 300 mmHg+-100 mmHg (40.7kPa+-13.3kPa)
Alarm
Infusion Complete, Empty, Faulty Signal, Misoperation, Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle.
Air Bubble Detector Method
ultrasonic wave, sensitivity: more than or equal
25 μL
Fuse
F1AL/250V ("F" indicate fast,"L" indicate low breaking capacity), 2Â pcs (installed inside pump).
Power Supply
AC 85~265V, 50/60Hz;
Internal Battery
11.1V rechargeable li-ion battery. Capacity:more than or equal 2000mAh;
the pump can work more than 4Â hours at the flow rate of 25 ml/h after charging for 8Â hours (Medium rate specified by GB 9706.27-2005).
Power
less than or equal 40VA
Size
188 mm(L)*198 mm(W)*228 mm(H)
Weight
2.2KG
Environment Requirements
Transport
Ambient Temperature: -30°C~+55°C
Relative Humidity: 20%~95% (non-condensing)
Atmosphere Pressure: 70kPa~106kPa
Storage
Ambient Temperature: -30°C~+55°C
Relative Humidity: 20%~95%
Atmosphere Pressure: 70kPa~106kPa
Operation
Ambient Temperature: +5~+40°C
Relative Humidity: 20%~90%
Atmosphere Pressure: 86kPa~106kPas
Calibration function
disposable IV set of any brand is suitable for this pump
Three working modes
Rate/Volume/Time mode
Alarm
Infusion Complete, Empty, Faulty Signal, Misoperation, Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle.
infusion monitoring system (Optional),
the status of each pump is displayed in real time at the central station through wireless transmission.
4.3 inch color LCD display, with backlight, suitable for working in various ambient light conditions.
Display time, battery, infusing status, mode, rate, target volume, accumulated volume, target volume, sound volume, pressure, department, bed No., I/V set, temperature of medication
Technical Specification:
Infusion rate range
Adjustable drop rate range: 1Â /min~400 drops/min
                          (step: 1 drop /min)
Adjustable flow rate range: 1ml/h~1200ml/h
                         (step 0.1ml/h)
Purge rate: 800ml/h
KVO rate: 1ml/h (1~300ml/h)
         3ml/h (greater than 300ml/h)
Infusion volume range: 1ml~9999.9ml (step: 0.1 ml)
Maximum accumulated volume: 9999.9ml (step: 0.1 ml)
Infusion Time range: 1min~9999min (step: 1Â min)
Infusion accuracy: Within ±3% (using calibrated high quality IV set)
                   Mechanical precision: within ±2%
Occlusion alarm threshold:
         High: 800 mmHg ± 200 mmHg (106.7kPa±26.7kPa)
Medium: 500 mmHg ± 100 mmHg (66.7kPa±13.3kPa)
Low: 300 mmHg ± 100 mmHg (40.7kPa±13.3kPa)
Alarm: Infusion Complete, Empty, Faulty Signal, Misoperation, Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle.
NIBP
Range
Average deviation: ≤ ±5mmHg
Standard deviation:  ≤ 8mmHg
Adult
         SYS: 40mmHg~280mmHg
         MEAN: 20mmHg~240mmHg
         DIA: 10mmHg~220mmHg
Pediatric
         SYS: 40mmHg~220mmHg
         MEAN: 20mmHg~170mmHg
         DIA: 10mmHg~160mmHg
Neonate
         SYS: 40mmHg~135mmHg
         MEAN: 20mmHg~110mmHg
         DIA: 10mmHg~100mmHg
Static pressure
         Range: 0mmHg~300mmHg
         Deviation: 3mmHg
Resolution: 1mmHg
NIBP measurement mode
Manual
Cycle (automatic):
Optional interval: 1min, 2min, 3min,4min, 5min, 10min,
15min, 30min, 60min, 90min
Fast: continuous NIBP measurement, interval is 5min
NIBP alarm
High pressure alarm: >90mmHg-160mmHg
Low pressure alarm: <50mmHg-90mmHg
Accuracy: ±5%
Overpressure protection
Adult: 280 mmHg ±10 mmHg
Pediatric: 237 mmHg ±3 mmHg
Neonate: 147 mmHg ±3 mmHg
SpO2
Range: 0%~100%
Resolution: 1%
Accuracy: 70% to 100%, precision is 2%
          0% to 69%, undefined
SpO2 alarm
Upper limit: 100%
Lower limit: 90%
Alarm value accuracy: 3%
Alarm time accuracy: 2s
Pulse rate
Range: 20bpm~300bpm
Resolution: 1bpm
Accuracy: 3bpm
Pulse rate alarm
Upper limit: 120bpm
Lower limit: 50bpm (default)
Alarm value accuracy: 5%
Alarm time accuracy: 2s
NIBP Cuff requirement
Human body contact materials: Waterproof cloth
Size: 515mm(L)×145mm(W), allowed deviation: ±5%
SpO2 sensor
Type: Finger clip type
Wire length: 3000mm, allowed deviation: ±5%
Human body contact materials: Silicone
Size: 188 mm(L)×198 mm(W)×228 mm(H)
Net weight: 2.2kg
Â
Model NO.: YSD186-Vet
Group: Human and Veterinary
Needle: With Needle
Syringe Use: Intramuscular Injection
Disinfection: Without Disinfection
Medical Devices Ad. Approval No.: 20142540865
Medical Device Regulatory Type: Type 2
Type.: Infusion Pump
Theory: Electrotherapeutics
Pumping Way: Peristalic Fingers
Pump Type: Drip Type Infusion Pump
Adjustable Drop Rate Range: 1~400 Drops/Min (Step: 1 Drop/Min)
Purge Rate: 800 Ml/H
Standard.: Ce ISO
Origin.: China
Kvo Rate: 1 Ml/H (1~300 Ml/H)
Net Weight: 2.2 Kg
Trademark: CE
Transport Package: in Carton Packing
Specification: 188MM*198MM*228MM
Origin: China Chengdu
HS Code: 9018907000